Development of a fluorescent light technique for evaluating microdamage in bone subjected to fatigue loading
Sarandeep S. Huja; M. Sayeed Hasan; Ramana Pidaparti; Charles H. Turner; Lawrence P. Garetto; David B. Burr (Profiled Author: David B. Burr)
Journal of Biomechanics. 1999;32(11):1243-1249.
AbstractA new method using fluorescent light microscopy has been developed to visualize and evaluate bone microdamage. We report the findings of two different experiments with a common aim of comparing the fluorescent light technique to the brightfield method for quantifying microdamage in bone. In Experiment 1, 36 canine femurs were tested in four-point cyclic bending until they had lost between 5 and 43% of their stiffness. The loaded portion of the bone was stained en bloc with basic fuchsin for the presence of damage. Standard point counting techniques were used to calculate fractional damaged area (Dm.Ar=Cr.Ar/B.Ar, mm2/mm2) under brightfield and fluorescent microscopy. In Experiment 2, bone microdamage adjacent to endosseous implants, subjected to fatigue loading (150,000 cycles, 2Hz and 37°C) ex vivo was examined. The bone around the implant was either allowed to heal (adapted specimen) for 12 weeks after placement in dog mid-femoral diaphyses prior to testing or was loaded immediately to simulate non-healed bone surrounding endosseous implants (non-adapted). Crack numerical density (Cr.Dn=Cr.N/B.Ar, #/mm2), crack surface density (Cr.S.Dn=Tt.Cr.Le/B.Ar, mm/mm2) and fractional damaged area were calculated separately by both techniques in the adapted and non-adapted specimens. In both Experiments 1 and 2, significantly more microdamage was detected by the fluorescent technique than by the brightfield method. Also, there was a trend towards higher intraobserver repeatability when using the fluorescent method. These results suggest that the brightfield technique underestimates microdamage accumulation and that the fluorescent technique better represents the actual amounts of microdamage present. The results demonstrate that the fluorescent method provides an accurate and precise approach for bone microdamage evaluation, and that it improves the prediction of stiffness loss from damage accumulation. Copyright (C) 1999 Elsevier Science Ltd.
PMID: 10541076
Scientific Context
This section shows information related to the publication - computed using the fingerprint of the publication - including related publications, related experts with fingerprints representing significant amounts of overlap between their fingerprint and this publication. The red dots indicate whether those experts or terms appear within the publication, thereby showing potential and actual connections.
Related Publications
-
1.
2007Jason W. Triplett; Rita O'Riley; Kristyn Tekulve; Suzanne M. Norvell; Fredrick M. Pavalko
MCB Molecular and Cellular Biomechanics. 2007;4(1):13-25. -
2.
1994J.A. Vilensky; B.L. O'Connor; K.D. Brandt; E.A. Dunn; P.I. Rogers; C.A. DeLong
Journal of Orthopaedic Research. 1994;12(2):229-237. -
3.
2001Lindsey D. Mayo; Kelly M. Kessler; Roxana Pincheira; Robert S. Warren; David B. Donner
Journal of Biological Chemistry. 2001;276(27):25184-25189.
Related Topics
Appears in this Document
Related Experts
Author of this Document
-
Internal ExpertsPublications
-
287









-
89









-
36









-
197









-
57









-
91