Scopus Publication Detail
The publication detail shows the title, authors (with indicators showing other profiled authors), information on the publishing organization, abstract and a link to the article in Scopus. This abstract is what is used to create the fingerprint of the publication.
Magnetic resonance imaging of pulmonary parenchymal disease using a modified breath-hold 3D gradient-echo technique: Initial observations
Till R. Bader; Richard C. Semelka; Monica S. Pedro; Diane M. Armao; Mark A. Brown; Paul L. Molina (Profiled Authors: Paul L Molina; Richard C Semelka; Diane M Armao)
Journal of Magnetic Resonance Imaging. 2002;15(1):31-38.
AbstractPurpose: To determine the potential of a modified breath-hold 3D gradient-echo technique for visualizing pulmonary parenchymal diseases. Materials and Methods: Twenty-one magnetic resonance imaging (MRI) studies of the lungs were performed in 20 patients (15 male and 5 female; age range, 7.7-86.1 years) with pulmonary diseases comprising non-small-cell, small-cell, and bronchioalveolar carcinomas, endobronchial mucoepidermoid carcinoma, metastases, pneumonia, Wegener's granulomatosis, chronic obstructive pulmonary disease, arterio-venous malformation, and bronchogenic cyst. Confirmation of diagnoses was obtained via histopathology (14 patients) and follow-up (6 patients). MRI studies were performed at 1.5 T before and after administration of gadolinium using a modified volumetric interpolated breath-hold examination (VIBE) sequence. All images were evaluated prospectively regarding lesion detection and characterization. MR findings were correlated with final diagnoses. Retrospective grading (scores, 1-4) was performed for general image quality (rated "poor" to "excellent"); presence of artifacts ("negligible" to "severe"); and imaging quality of pulmonary lesions (conspicuity and contrast on pre- and postgadolinium images). Results: Twenty-three solid pulmonary lesions, 25 infiltrates and segmental atelectases, and 1 cyst were detected and prospectively correctly diagnosed. Sizes ranged from 0.3-10 cm. The mean scores for image quality and presence of artifacts were 3.3 (SD, 0.7) and 1.8 (SD, 0.7), respectively. Conspicuity and contrast of pulmonary lesions received mean scores between 3.0 and 3.8 (SD, 0.4-0.7). Conclusion: This MRI technique allows imaging of a wide spectrum of solid and nonsolid pulmonary parenchymal diseases with reproducible high image quality, effective suppression of artifacts, high resolution, and visualization of gadolinium enhancement.
PMID: 11793454
Scientific Context
This section shows information related to the publication - computed using the fingerprint of the publication - including related publications, related experts with fingerprints representing significant amounts of overlap between their fingerprint and this publication. The red dots indicate whether those experts or terms appear within the publication, thereby showing potential and actual connections.
Related Publications
-
1.
2000Richard C. Semelka; N. Cem Balci; Kathy P. Wilber; Laurie L. Fisher; Mark A. Brown; Andres Gomez-Caminero; Paul L. Molina; Richard C. Semelka
Journal of Magnetic Resonance Imaging. 2000;11(2):195-200. -
2.
2000Peter Van Gelderen; Cécile Grandin; Jeffrey R. Petrella; Chrit T. W. Moonen
Rapid three dimensional MR imaging method for tracking a bolus of contrast agent through the brain
Radiology. 2000;216(2):603-608. -
3.
2009Miguel Ramalho; Vasco Herédia; Masakatsu Tsurusaki; Ersan Altun; Richard C. Semelka
Journal of Magnetic Resonance Imaging. 2009;29(4):869-879.
Related Topics
Appears in this Document
Related Experts
Author of this Document
-
Internal ExpertsPublications
-
343
-
181
-
125
-
137
-
59
-
90

